UA-3101-080 is the default front panel for LAN-XI CAN Bus Module Type 3058-080, having two independent CAN Bus input connectors. This front panel is ideal for automotive noise, vibration and harshness (NVH) applications. USE SCENARIOS CAN Bus applications, including in-vehicle measurements using Sonoscout Automotive sound quality metrics General sound and
UA-3100-042 is designed for use with Generator, 4/2-ch. Input/Output Module Type 3160-A-042. USE SCENARIOS General purpose sound and vibration measurements Direct voltage CCLD microphones CCLD accelerometers CCLD tacho probes Generator output Connector type: BNC Front panel Compatible LAN-XI modules UA-3100-042 Type 3160-A-042
The Array front panel for LAN-XI UA-2145 is intended for use with hand-held microphone arrays together with a LAN-XI Frame 3660-D. USE SCENARIOS Noise source identification using mapping techniques in conjunction with Acoustic Holography Calculations, Conformal Mapping Calculations and a 3D positioning system Suitable for use with Handheld Arrays: Type
UA‐2121‐030 is the front panel used with LAN‐XI Bridge Module Type 3057‐B‐030. The front‐panel has 3 × 15‐pin sub‐D connectors which allow individual configurations of completion resistors to be made directly on the cable plug. USE SCENARIOS Bridge sensor measurements: 1/1, 1/2, 1/4 bridge strain gauges Strain gauge based sensors
The UA-2120-060 allows up to six charge type transducers to be connected directly to the LAN-XI frontend, simplifying setup and performance. USE SCENARIO Charge type transducers: Accelerometers, pressure sensors, hydrophones The frontpanel has six integrated charge amplifiers, each with a fixed gain of 0dB (-1mV/pC) and a fixed High-Pass Filter
The UA-2119-060 allows up to six differential charge accelerometers, such as Type 8347-C, to be connected directly to the LAN-XI frontend, simplifying set-up and optimising performance. USE SCENARIOS Differential charge accelerometers Environments with high levels of electromagnetic noise Applications where good ground connections is difficult to achieve High immunity for
UA-2118-022 is a dedicated analogue interface for headphone testing allowing simultaneous testing of left and right headphones. A three-position switch on the front panel switches the output of Generator 1 between left earphone, both earphones and right earphone. USE SCENARIO Testing of headphones, small loudspeakers and receivers Connector type: LEMO,
The UA-2117-011 is the default front panel for the 200 kHZ LAN-XI module Type 3161-A-011. USE SCENARIOS High-frequency sound and vibration measurements Underwater acoustics applications High-energy impact measurements High-frequency system excitation and transducer calibration The front panel has three different input connectors, BNC/ LEMO/ TNC, that allow connectivity for a
The UA-2116-120 allows up to 12 charge type transducers to be connected directly to the LAN-Xi front end, simplifying the setup and the performance. USE SCENARIOS Charge type transducers: Accelerometers, pressure sensors, hydrophones Combustion pressure monitoring on up to 12-cylinder engines High channel count charge accelerometer applications Ideal for high
The UA-2114 front panels are specifically designed for use with Kulite Bridge Transducers such as the LQ-080 series and the LQ-125 series used in the aerospace industry for dynamic measurements on aircraft and in wind tunnels. USE SCENARIO Kulite Bridge Transducers UA-2114 is supplied from ±5 V and deliver ±5
The UA-2113 front panel provides buffered monitors outputs in parallel to the inputs. It allows input signals to be simultaneously fed into both the LAN-XI system and also a second system like a recorder. USE SCENARIOS Monitor outputs General purpose sound and vibration measurements Direct Voltage CCLD Microphone CCLD Accelerometer
The UA-2112 front panels features 2 and 4 multi-pin connectors for six array microphones. It is primarily intended for Array Acoustic systems. USE SCENARIO Array acoustics Connector type: LEMO Front panels Compatible LAN-XI modules UA-2112-120 Type 3053-B-120 UA-2112-060 Type 3050-A-060
The UA-2111 is the default front panel on both LAN-XI Type 3056 auxiliary module. It features 4 x BNC connectors for general sound and vibration measurement and 2 x 10-pin LEMO connectors for 8 channel auxiliary signal inputs. The auxiliary channels are connected using the auxiliary cable: AO-0738-D-010. USE SCENARIOS Low-frequency auxiliary
The UA-2110 is an auxiliary front panel designed for applications combining auxiliary data with microphones that require 200V polarization voltage. It features 4 x LEMO (7 pin) connectors for 200V microphones and has 2 x 10-pin LEMO connectors for 8 channel auxiliary signal inputs. The auxiliary channels are connected using
The UA-2109 front panel features a single 50-pin Sub-D connector and is primarily for applications where customised non-standard cables are required. USE SCENARIOS General purpose sound and vibration measurements with user-customized cables Direct voltage CCLD accelerometer Charge accelerometer (using charge adaptor) CCLD microphone CCLD tacho Probe Connector type: Sub-D
The UA-2108 front panels features 2 and 4 x 4-pin triax accelerometer connectors. It reduces the number of cables by two thirds when used with CCLD triax accelerometers. USE SCENARIO CCLD triax accelerometer Connector type: -pin Microtech Front panels Compatible LAN-XI modules UA-2108-120 Type 3053-B-120 UA-2108-060 Type 3050-A-060
The UA-2107 is the default front panel for the 12-channel Type 3053 input module. Compact SMB connectors allow for easy connection for direct voltage, CCLD accelerometer, charge accelerometer (using charge adaptor), CCLD microphone and CCLD tacho probe. USE SCENARIOS General purpose sound and vibration measurements Direct voltage CCLD microphone CCLD accelerometer CCLD
The UA-2105 is intended for use with charge accelerometers. It features six slots for direct mounting of up to six In-line Charge Amplifiers, Type 2647. USE SCENARIO Charge accelerometers Connector type: Type 2647 sockets Front panel Compatible LAN-XI modules UA-2105-060 Type 3050-A-060
The UA-2104 Front Panel is intended for Sound intensity measurements on PULSE using the Sound Intensity Probe Type 3599. Used with an additional connector( BNC) for accessing generator output 2 on LAN-XI type 3160-A-042 or accessing input 6 on LAN-XI type 3050-A-060. USE SCENARIOS Sound intensity measurements using PULSE Selective intensity measurements
The UA-2103 front panel features a single 37-pin Sub-D connector. It is primarily intended for backwards compatibility with our previous Array Acoustic systems. USE SCENARIOS Array acoustics General purpose sound and vibration measurements with user customized cables. Direct voltage Generator output CCLD accelerometer Charge accelerometer (using charge adaptor) Microphone preamplifier
The UA-2102 front panels mixes up to 4 circular 7-pin connectors and 2 BNC connectors. These front panels allow input and conditioning for direct voltage, generator output, CCLD accelerometer, CCLD microphone, CCLD tacho probe (using AO-0091 adaptor cable), charge accelerometer (using in-line charge adaptor –Type 2647 and AO-0091), DC responding