For use on sound level meters Type 2250-S and Type 2270-S, the application assesses a variety of building acoustic parameters according to a wide range of national and international standards. USE SCENARIOS Airborne sound insulation Façade sound insulation Impact sound insulation The application guides users through all necessary reverberation and level measurements in
This standard software, included in the basic package for Types 2250-S and -W and 2270-S and –W, provides a single, wide dynamic range that is combined with simultaneous measurement of RMS and peak levels with different frequency and time weightings so you can gather all information in one go. The
BZ-7131 provides 1/1-octave spectra (centre frequencies 16 Hz to 8 kHz) and BZ-7132 provides 1/3-octave spectra (centre frequencies 12.5 Hz to 16 kHz). Both applications have spectral statistics based on LAF or LAS and a dynamic range from the noise floor in each individual band to a maximum level of
This standard software included in the basic applications package for Type 2250 Light provides a single, wide dynamic range combined with simultaneous measurement of RMS and peak levels with different frequency and time weightings so you can gather all information in one go. The sound level meter template also offers
The Logging application also can log spectra if Frequency Analysis Software BZ-7131 or BZ-7132 is installed. During measurement, markers and annotations can be added to the profile. With Signal Recording Option BZ-7226 installed, signal recordings can be made to document events as they happen. USE SCENARIOS Environmental noise monitoring with Type 2250-S, Type 2270-S and Type 2250 Light sound level
When used in conjunction with the FFT Analysis or Frequency Analysis application for sound level meters Type 2250 and Type 2270, or the Frequency Analysis application for the Type 2250 Light, this option provides an objective assessment of tonal noise components. The analysis is fully automatic, identifying all tones in the measured spectrum. On
The application supports two reverberation time measurement methods: impulsive excitation (Schroeder Method) and interrupted noise. In the impulsive excitation method, Type 2250-S automatically measures reverberation time when a balloon burst or starter pistol is used to excite the room. In the interrupted noise method, the sound level meter intelligently controls a loudspeaker
This sound level meter software for Type 2270 is usually used together with a sound intensity probe, to assess sound levels and give instant results. This system makes it easy for one person to perform a sound intensity measurement from beginning to end. By scanning the object, you can get
This option enhances functionality in Sound Level Meter BZ-7222, Frequency Analysis BZ-7223 and Enhanced Logging BZ-7225applications. It enables infrasound and building vibration measurements to be performed according to the most important international standards. For infrasound measurements, use low frequency microphone Type 4193 or Type 4964 optionally with the LF adaptor UC-0211. For building vibration measurements, use accelerometer Type 8344. For peak
This system makes it easy for one person to perform a sound intensity measurement from beginning to end. It includes a sound level meter, a two-channel sound intensity probe, and the necessary software. By scanning the object or measuring point by point, you can get on-the-spot noise source identification results
MATRON 4 is an indoor noise logging kit based on a Type 2250 Light sound level meter with class 1 measurement and sound recording capabilities. Typically used for domestic noise assessments, the system is ideal for medium-term logging in home or office environments. Once set up, the sound level meter, protected by
Type 2270-W is a compact and rugged 2-channel hand-held analyzer that comes without preamplifier. Connect one or two accelerometers and Type 2270-W is a highly accurate vibration meter. The instrument comes with an applications package which enables basic vibration measurements of level and crest factor. More advanced measurement tasks such
Type 2270-S is a compact and rugged class 1 type-approved 2-channel sound level meter with all the capabilities of Types 2250-S and -2250-W, plus the benefits of two independent channels. This allows the meter to measure simultaneously with two microphones, two accelerometers or one of each, potentially halving measurement time.
Type 2250-W is a compact and rugged hand-held analyzer. With the addition of an appropriate accelerometer, Type 2250-W is a highly accurate vibration meter. The instrument comes with applications for basic vibration measurements of level and crest factor. More advanced measurement tasks such as vibration source identification, machinery analysis and troubleshooting, and
These hand-held analyzers are rugged and easy-to-use class 1 sound level meters. They come with the basic applications package for Type 2250 Light, a microphone and a preamplifier: everything you need to immediately and easily get started with general sound level meter tasks, as well as occupational health and safety (OHS),
Type 2250-S is a class 1 sound level meter (SLM) that comes with the microphone, preamplifier and basic applications you need to get started with accurate environmental, occupational and industrial measurement tasks. It is rugged enough for the field yet precise enough to go straight to the lab. Type 2250-S can be expanded
B&K 2245 Sound Level Meter is designed to be used when and where you have a job to do. Robust and dust- and water-resistant to IP55, this sound level meter (SLM) can be used in the field surrounded by grit, grime or inclement weather. But just because the SLM can take
This solution for B&K 2245 Sound Level Meter is a complete, focused toolset for measuring occupational noise-related concerns, such as noise exposure surveys and risk mitigation for noise-induced hearing loss. With an IP55 rating, the sound level meter itself is more than durable enough to be used in just about any work
This B&K 2245 Sound Level Meter solution is a focused toolset for measuring exhaust noise. Rated IP55, this system is durable enough to be used in the shop or on the street. Whether you are performing stationary exhaust noise testing in a workshop or performing street-side spot checks for law enforcement, this
This environmental noise solution for B&K 2245 Sound Level Meter is a complete, focused toolset for measuring and reporting on environmental noise concerns. The sound level meter’s IP55 rating ensures that you can set up and measure where you need to be, without having to worry about exposure to water or dust,