Signal Conditioning

PME Industrial Amplifiers
PME – The Industrial Measurement Signal Conditioners Linked to a Fieldbus
The intelligent PME measurement system is ideal for use in decentralized measurement applications within the industry, such as production processes with large machinery as well as for functional and power test stands. Additionally, it is also suited for areas with potentially explosive atmospheres. Its stand-alone amplifier modules record relevant measured quantities, such as force, pressure, temperature, rotational speed, and torque for internal digital processing. A free software assistant and standard fieldbus interfaces such as CAN and PROFIBUS DP allow for fast integration of the modules.
- HBM accuracy class: from 0.1 to 0.03
- Measurement channels: from 1 to 8
Please note: As of 2019, most PME modules have been replaced by HBM’s ClipX Signal Conditioner.
MP55, MP55DP, MP60 and MP60DP remain available
PME modules at a glance
MP01 – Multichannel measurement amplifier
DC amplifier; 4 channels for voltage, current, and thermocouples or 2 channels for PT100 and resistors; Subcon5 connector; 0.1 accuracy class
MP30 – Single channel measurement amplifier
600 Hz carrier frequency amplifier for strain gage transducers; 0.05-20 Hz filter; autocalibration; 0.03 accuracy class
MP30DP – Single channel measurement amplifier
600 Hz carrier frequency amplifier with the same characteristics as MP30 (see above) but with an additional PROFIBUS DP interface
Note: In combination with SD01A Zener barriers, sensors can also be operated as intrinsically safe devices in potentially explosive atmospheres, measurement circuit type[S.B.1] (Ex II (1) GD, [EEx ia]IIC).
MP55 – Single channel measurement amplifier
4.8 kHz carrier frequency amplifier for strain gage and inductive transducers in full and half bridge circuit; 0.05-500 Hz filter; 0.1 accuracy class
MP55DP – Single channel signal conditioner
4.8 kHz carrier frequency amplifier with the same characteristics as MP55 (see above), and with an additional PROFIBUS DP interface
MP55IBS – Single channel signal conditioner
4.8 kHz carrier frequency amplifier with the same characteristics as MP55 (see above), and with additional Interbus S interface
Note: In combination with SD01A Zener barriers, sensors can also be operated as intrinsically safe devices in potentially explosive atmospheres, measurement circuit type [S.B.1] (Ex II (1) GD, [EEx ia]IIC).
MP60 – Single channel signal conditioner for incremental transducers
Frequency measuring module for incremental transmitters and HBM torque flanges with frequency output; 0.05 accuracy class
MP60DP – Single channel measurement amplifier for incremental encoders
Frequency measurement module with the same characteristics as MP60 (see above), and with an additional PROFIBUS DP interface
MP70DP S7 – Profibus interface
Gateway from CANopen to Profibus DP; up to 8 PME channels can be connected via CAN; enables gateway functions and mathematical functions to be realized.