Transport Shock Monitoring

MONI LOG® MicroShockDetector

MONI LOG® MicroShockDetector

Compact, light-weight shock data logger

  • Registers the 200 largest shock events in the X, Y, Z direction
  • Saves up to10 curve progressions of the largest shocks
  • Intelligent filtering and evaluation
  • Indicates limit value overruns with alarm LED
  • Continuous temperature recording
  • Intuitive operation, extremely long and independent operation time
  • Communication via USB
  • Easy configuration and evaluation with license-free PC software
  • Configurable recording over start-stop time
  • Easy mounting with adhesive pad, screws or magnetic feet

High-sensitivity devices, e.g. large, superconducting magnets in medical technology, need a safe and demonstrable protection during transport or during storage. The limit value monitoring function of the MONI LOG® MicroShockDetector replaces the more costly, high-end data loggers without compromising measurement data.

Smaller than a smartphone, this micro-measuring device weighs only 180 grams. It reliably stores all shock data in 3 axes, sets the data collected into acceleration classes, supplies curve-plots and activates an alarm as soon as limit-values are exceeded while continuously monitoring temperature.

The switch-on time of the MONI LOG® MicroShockDetector are simple to configure. Using the USB port, all data can be read, configured and evaluated on a PC.

The device can be mounted and removed quickly by means of an adhesive pad, screws, or a set of magnetic adhering feet supplied. On the basis of the good environmental and economical parameters is it also justifiable to use the unit also only once.

Technical Data
Shock parameters: 200 data record evaluation according to space vector amplitude, with curve-plots over 4 s for the 10 highest values resolution 2 ms
Acceleration sensor: 3D-MEMS, measuring range ±8 g; 1mg resolution
±(2 % measuring range + 5 % measurement value) at 13 Hz / 20 °C
±(3 % measuring range + 6 % measurement value) at 13 Hz / -20 °C / +60 °C filter limit frequency 25 Hz fixed-adjusted
Shock classification: Subdivision of shocks according to space vector amplitude into classes, number of shocks not limited > 0.25 g; > 0.5 g; > 1 g; > 1.5 g; > 2 g; > 3 g; > 4 g; > 5 g
Temperature measurement: -40 °C to +65 °C ±1 K; 100,000 measurement values
Indication: 2 LED‘s, for status and alarm limit-value overshooting
Operating controls: 1 button for status indicator, ON/ OFF switching with password protection
Connections: Mini USB 2.0
Operating conditions: -40 °C to +65 °C; max. 98 % rel. humidity
Power supply: 1 replaceable lithium battery 3.6 V, type LR06 (AA, Mignon), non hazardous goods
runtime typically 12 months in switch-on time period (depending on the device configuration)
Data receipt: Receipt of measuring data independent of battery status for a minimum of 10 years
Dimensions: 108 mm x 48 mm x 30 mm (L x W x H), 146 mm x 50 mm x 40 mm (L x W x H with magnetic feet)
Housing: Plastic housing with stainless steel base
Weight: approx. 172 g (258 g total if mounted on magnetic feet)
Protection type: IP 67
Programmable parameters: X, Y, Z registering threshold, X, Y, Z alarm threshold, minimum shock duration, temperature-measurement interval Start-Stop time (switch-on time period), password protection by means of free Windows software