HBM - Archive

ZZZ – CLIP Analog Amplifier for Industrial Applications

ZZZ – CLIP Analog Amplifier for Industrial Applications

OBSOLETE PRODUCT – page for information and support purposes only.

see HBM – ClipX digital industrial amplifier for replacement

 

Simply ‘clip on’ and get started! The CLIP analog amplifier comes in a lightweight plastic housing. It is designed for applications in production or test benches, and can be easily installed on DIN rails. CLIP modules have DC or CF supply and can be connected to all strain gauge transducers for measuring force, displacement or torque as well as load cells. Moreover, many modules are available for expansion and individual adaptation to respective applications. CLIP combines quick integration and ease of use, and is a cost-effective solution for reliably acquiring physical quantities in harsh industrial environments.

HBM accuracy class: 0.1
Measuring inputs for many common signals in production and test benches
Optional expansion with: current output, limit switch, tare module

Please note: Clip is available until the end of 2019 and is being replaced with the new and precise signal conditioner ClipX!

CLIP modules at a glance

AE101

DC amplifier for strain gauge full bridges; for static and dynamic measurements (<6kHz); selectable excitation voltage; 0.1 … 8mV/V measuring range

AE301

CF amplifier (600Hz) for strain gauge full bridges; very high zero point stability; up to 4 strain gauge transducers can be operated in parallel; 0.03% typ. linearity error; 0.2 … 8mV/V measuring range

AE501

CF amplifier (4.8 kHz) for inductive half and full bridges; 8 … 400mV/V measuring range

GR201

Dual limit switches with 2 separate inputs; reference voltage adjustable between ?0V and +10V; switching direction, hysteresis and switching time can be selected

TS101

Automatic tare and store unit; acquisition of peak values and instantaneous values; envelope curve function selectable

EM201, EM201K2

Single and/or dual find stage for +20mA or +4 …+20mA current output; permissible load resistance <500 Ohm

NT101A, NT102A

Power supply for modules (230V, 115V/50 … 60Hz); up to 4 modules can be connected (15V= / max. 650mA); with overload protection